EASYMAX blood glucose test strips box of 50 foil strips

Insert the blood sample into the blood collection area at the tip of the test strip. The test strip will draw the blood sample into the reaction area. Glucose dehydrogenase bound to FAD catalyzes the dehydrogenation of glucose. The reaction produces gluconolactone. During the reaction, an intermediate transfers electrons to the electrode surface and generates an electric current. The amount of current is proportional to the amount of glucose present in the blood sample. After 5 seconds, the EASYMAX Series meter will show the glucose concentration on the screen.
379,000 ₫
  • Brand: EasyMax
  • Factory: Taiwan
  • Use for: Glucose Monitoring
  • Features:
    • Enamel GDH-FAD test strips. Does not react with confusing substances in blood samples: oxygen, maltose, galactose, ...
    • High substrate specificity without interference up to 61 substances. Consists of mostly endogenous and exogenous substances. Unaffected by commonly prescribed diabetes/hypertension medications.
    • No-coding technology
    • Shelf life 12 months from opening
    • Technology to detect when not enough blood samples are taken
  • Preserve in cool and dry place.
  • Taiwan
FAD glucose dehydrogenase
(Aspergillus oryzae, 2.0 IU/test strip)
6 (w/w) %
Potassium ferricyanide 56 (w/w) %
Non-reactive ingredients 38 (w/w) %

  • CE 0537
  • FDA
  • ISO 15197:2013
  • 50 test strips (separated) / box

Other Products

  • Enamel test strips GDH-FAD
  • High substrate specificity with no interference up to 61
  • No-coding technology
  • Shelf life 12 months from opening
  • Technology to detect when not enough blood samples are taken
  • Enamel test strips GDH-FAD
  • High substrate specificity with no interference up to 61
  • No-coding technology
  • Shelf life 12 months from opening
  • Technology to detect when not enough blood samples are taken
  • Test strip push button
  • Mark multiple users
  • Backlit LCD Display
  • Not enough samples report
  • USB - PC Connector
  • Enamel test strips GDH-FAD
  • High substrate specificity with no interference up to 61
  • No-coding technology
  • Shelf life 12 months from opening
  • Technology to detect when not enough blood samples are taken
Mới
  • Automatic blood glucose level classification
  • NFC wireless connection technology
  • Utility app EZGlucoTag
  • Mark results Before/After meals
  • Calculate the average result 7/14/30/90 days
  • Mark results Before/After meals
    Differentiate blood sugar levels before/after meals
  • Calculate the average result 7/14/30/90 days
  • Low blood sugar warning